Grinding When You Use Thoriated Tungsten Electrodes
- Details
- Category: Tungsten Information
- Published on Tuesday, 07 May 2013 10:53
Grinding creates the greatest hazard as the exposed tungsten/thoria area is greatly increased and fine particles of potentially radioactive dust are released into the atmosphere.
It is recommended that a dedicated grindstone with local dust extraction is used, and a simple filter mask is worn unless the number of electrodes used is very small (less than about 20 per year). If the grinding wheel is not fitted with a protective viewing screen, eye protection should be worn. The air extract from the grindstone should be arranged so that the particles are deposited into a substantial disposable bag.
A safe method of collecting and handling the dust from the collection unit must be used to minimise release to the atmosphere (for example, it could be placed in a sealed paper/plastic bag.)
The area round the grinding wheels should be cleaned daily with a vacuum cleaner to remove dust particles. If a high efficiency vacuum cleaner is not available, then the material should be damped down to minimise dust.
Workers should be encouraged to wash their hands before using the toilet facilities, and before taking work breaks, and for this reason the washing facilities should be close to the work areas.