Overhaul Tungsten Points’ Ablation in Distributor - IV
- Details
- Category: Tungsten Information
- Published on Wednesday, 15 July 2015 16:39
6. Overhaul the capacity of capacitor.
Placing the capacitor flatly on the cylinder head and grounding the housing, and then aligning the high voltage bus with capacitor wire head about 5mm. Then you should strike the tungsten points of the distributor, so the high-voltage current can charge in the capacitor by 4-5times. You should move the head of capacitor wire into the housing of 3mm around. If the following phenomenon appears: Flashover, with weak, dark red spark and small sound, it shows that the capacity of the capacitor is small and you should replace it; if the capacity of the capacitor is large, the following phenomenon will appear, and it shows that you don’t need to change it. Phenomenon: flashover, with louder sound and blue sparks.
7. Overhaul the connection of battery wire.
You should eliminate the oxide of each wire connector and tighten the wires.
8. Overhaul the generator.
In order to avoid the situation that the engine is operating in a low speed for a long time, you can increase the contact gap of tungsten points appropriately.