Gamma Camera Tungsten Alloy Collimator
- Details
- Category: Tungsten Information
- Published on Friday, 05 June 2020 20:03
- Written by Yahong
- Hits: 1924

Tungsten alloy collimator is a key component that affects the imaging quality of gamma camera (γ camera). Tungsten alloy collimator on a gamma camera is to realize spatial positioning, so that rays from different spatial parts irradiate a specific position of the scintillator. Studies have shown that under the principle of taking into account both geometric resolution (or angular resolution) and detection sensitivity, reducing the transmission effect as much as possible is the core goal of γ camera collimator design.
Tungsten Alloy Post-patient Collimator Applied for CT Machine
- Details
- Category: Tungsten Information
- Published on Friday, 05 June 2020 20:02
- Written by Yahong
- Hits: 1897

Tungsten alloy post-patient collimator is present between the patient and the detector on a CT machine, which serves to ensure good image quality, minimize the interference of scattered rays from other directions, and to reduce unnecessary radiation doses for the patients. Tungsten alloy post-patient collimator improves the slice sensitivity profile by giving a more rectangular shape.
Read more: Tungsten Alloy Post-patient Collimator Applied for CT Machine
Tungsten Alloy Foil Applied for CT Detector
- Details
- Category: Tungsten Information
- Published on Friday, 05 June 2020 19:59
- Written by Yahong
- Hits: 1720

Tungsten alloy foil is an important anti-scattering component on a CT detector. And there may be 9-129 tungsten alloy anti-scatter foils on a CT detector. Research shows that anti-scattering foils made of high quality tungsten alloy is not easy to deform during long-term use, so the channel width will not change, avoiding signal distortion when X-rays pass through the deformed traditional ray channel, and ensuring imaging quality.
Tungsten Alloy Pre-patient Collimator Applied for CT Machine
- Details
- Category: Tungsten Information
- Published on Friday, 05 June 2020 20:00
- Written by Yahong
- Hits: 1793

Tungsten alloy pre-patient collimator is the tungsten alloy collimator located in front of the X-ray tube on a CT machine, with characteristics of high density, smooth surface and good dimensional accuracy. Tungsten alloy pre-patient collimator is the first component through which X-rays pass, and is mainly used to control the thickness of the scanning layer by controlling the width of the X-ray beam in the direction parallel to the long axis of the human body. The X-rays emitted from the X-ray tube are tapered, and becomes a thin beam after passing through the slit-shaped tungsten collimator.
Read more: Tungsten Alloy Pre-patient Collimator Applied for CT Machine
Tungsten Alloy Collimator Applied for CT Machine
- Details
- Category: Tungsten Information
- Published on Friday, 05 June 2020 19:58
- Written by Yahong
- Hits: 1839

Tungsten alloy collimator applied for medical CT machine includes tungsten alloy pre-patient collimator and tungsten alloy post-patient collimator. These collimators have the characteristics of high density, smooth surface and good dimensional accuracy.